Bolt tightening torque

Metric class 8.8 · 10.9 · 12.9 · A2-70 · SAE grade 2 · 5 · 8

tililt.com

Metric — N·m

Thread8.810.912.9A2-70
M3×0.51.31.92.21.0
M3.5×0.62.13.03.51.6
M4×0.73.14.45.12.4
M5×0.86.28.8104.8
M6×11115188.1
M7×118252914
M8×1.2525364320
M10×1.550728439
M12×1.758812614768
M14×2141201235109
M16×2218312365169
M18×2.5301431504234
M20×2.5426610712330
M22×2.5581831971451
M24×373610531231571
M27×3107915441805837
M30×3.51463209424471135

Unified — lb·ft

ThreadGr 2Gr 5Gr 8
1/4-20 UNC5.58.512
1/4-28 UNF6.39.714
5/16-18 UNC111725
5/16-24 UNF121927
3/8-16 UNC203144
3/8-24 UNF233549
7/16-14 UNC324970
7/16-20 UNF365578
1/2-13 UNC4975106
1/2-20 UNF5585120
9/16-12 UNC70109154
9/16-18 UNF78121171
5/8-11 UNC97150212
5/8-18 UNF110170240
3/4-10 UNC172267376
3/4-16 UNF192297420
7/8-9 UNC278429606
7/8-14 UNF306474669
1-8 UNC416644909
1-12 UNF456704995

Lubricated threads

ConditionNut factor KMultiply by
Dry, as received0.20× 1.00
Zinc plated0.18× 0.90
Lightly oiled0.15× 0.75
Moly / anti-seize0.12× 0.60

Tightening torque T = K·D·F for a preload of 75% of proof load, dry threads (K = 0.20). Lubricant lowers the torque for the same clamp — use the multiplier, or the bolt yields. Where the fastener or equipment maker publishes a figure, theirs wins.

Get the next chart before it's on the site

The Shop Sheet, once a month: one new printable chart, and one standards gotcha that catches people out — the kind of wrong number a forum thread or an AI answer gives with total confidence. No sales emails.

More printable charts

Tap Drill ChartEvery common metric, UNC and UNF thread with its tap drill and clearance hole. The one for the wall above the drill press.Drill Size ChartAll 163 number, letter and fractional drills in one ascending run, with decimal inch, millimetres and the tap each one drills for.Spanner & Allen Key ChartFor each bolt: the spanner or socket, the Allen key for its cap screw, the tap drill and the clearance hole.Wire Size ChartAWG ampacity at 60, 75 and 90 °C, and the copper size for any load and run length with voltage drop taken into account.Wire Ampacity Derating ChartHow far to derate copper for hot rooms and full conduits: temperature factors, conductor-count factors and the derated amps for every size from 14 AWG to 500 kcmil.Bearing Size ChartEvery common deep-groove ball bearing from 604 to 6320 by bore code and series, with what 2RS, ZZ and C3 mean.IEC Motor Frame ChartEvery IEC frame from 63 to 355: shaft height, foot hole spacing, shaft size and the kW normally built on it, plus B3/B5/B14.NEMA Motor Frame ChartNEMA T frames from 56 to 449T with shaft height, foot holes, shaft size and typical HP — and what C, TS and JM mean.Motor Full-Load Current ChartFull-load amps for three-phase motors at 208 to 575 V with the copper size for each, and typical IEC amps at 400 V.Motor Efficiency Class ChartMinimum efficiency for IE1 to IE4 at every standard rating, and which class the EU lets you buy now.IE3/IE4 Motor Compliance Chart (EU 2026)Which IE class a new motor must be in the EU, whether an old IE1 or IE2 motor may keep running or be rewound, and what an upgrade saves — with a checker for your nameplate.