Tililt

Printable bearing size chart

Every common deep-groove ball bearing from 604 to 6320 by bore code and series, with what 2RS, ZZ and C3 mean. One sheet, fits A4 and US Letter.

Download Excel (.xlsx) Print, or choose “Save as PDF” in the print dialog. The Excel file has every table as its own sortable tab.

Deep-groove ball bearing sizes

68 · 69 · 60 · 62 · 63 series · bore, OD and width in mm · suffix key

tililt.com

Bore code 00–20: bore d, then D × B for each series (mm)

Coded68xx D×B69xx D×B60xx D×B62xx D×B63xx D×B
001019×522×626×830×935×11
011221×524×628×832×1037×12
021524×528×732×935×1142×13
031726×530×735×1040×1247×14
042032×737×942×1247×1452×15
052537×742×947×1252×1562×17
063042×747×955×1362×1672×19
073547×755×1062×1472×1780×21
084052×762×1268×1580×1890×23
094558×768×1275×1685×19100×25
105065×772×1280×1690×20110×27
115572×9—90×18100×21120×29
126078×10—95×18110×22130×31
1365——100×18120×23140×33
1470——110×20125×24150×35
1575——115×20130×25160×37
1680——125×22140×26170×39
1785——130×22150×28180×41
1890——140×24160×30190×43
1995——145×24170×32200×45
20100——150×24180×34215×47

Miniature 60x / 62x: bore = the last digit

Coded60x62x
33—623 10×4
44604 12×4624 13×5
55605 14×5625 16×5
66606 17×6626 19×6
77607 19×6627 22×7
88608 22×7628 24×8
99609 24×7629 26×8

Suffixes

SuffixMeans
2RS / 2RSH / DDU / LLUsealed both sides (rubber)
RSsealed one side
ZZ / 2Z / 2ZRshielded both sides (metal)
Zshielded one side
C2clearance smaller than normal
C3clearance larger than normal
C4clearance larger than C3
Nsnap-ring groove in the outer ring
NRsnap-ring groove, snap ring fitted

Codes 00–03 are 10, 12, 15 and 17 mm; from 04 up the bore is the code × 5. 6204 = 62 series, 20 mm bore, 47 × 14.

Deep-groove ball bearings to ISO 15 boundary dimensions; the same number fits from any maker. d = bore, D = outside diameter, B = width, all in mm. Check the maker's catalogue for load and speed ratings.

Get the next chart before it's on the site

The Shop Sheet, once a month: one new printable chart, and one standards gotcha that catches people out — the kind of wrong number a forum thread or an AI answer gives with total confidence. No sales emails.

More printable charts

Tap Drill ChartEvery common metric, UNC and UNF thread with its tap drill and clearance hole. The one for the wall above the drill press.Drill Size ChartAll 163 number, letter and fractional drills in one ascending run, with decimal inch, millimetres and the tap each one drills for.Bolt Torque ChartTightening torque for metric property classes and SAE grades, with the multiplier for oiled and anti-seize threads.Spanner & Allen Key ChartFor each bolt: the spanner or socket, the Allen key for its cap screw, the tap drill and the clearance hole.Wire Size ChartAWG ampacity at 60, 75 and 90 °C, and the copper size for any load and run length with voltage drop taken into account.Wire Ampacity Derating ChartHow far to derate copper for hot rooms and full conduits: temperature factors, conductor-count factors and the derated amps for every size from 14 AWG to 500 kcmil.IEC Motor Frame ChartEvery IEC frame from 63 to 355: shaft height, foot hole spacing, shaft size and the kW normally built on it, plus B3/B5/B14.NEMA Motor Frame ChartNEMA T frames from 56 to 449T with shaft height, foot holes, shaft size and typical HP — and what C, TS and JM mean.Motor Full-Load Current ChartFull-load amps for three-phase motors at 208 to 575 V with the copper size for each, and typical IEC amps at 400 V.Motor Efficiency Class ChartMinimum efficiency for IE1 to IE4 at every standard rating, and which class the EU lets you buy now.IE3/IE4 Motor Compliance Chart (EU 2026)Which IE class a new motor must be in the EU, whether an old IE1 or IE2 motor may keep running or be rewound, and what an upgrade saves — with a checker for your nameplate.